• DocumentCode
    957403
  • Title

    Comparison of two wafer inspection methods for particle monitoring on semiconductor manufacturing

  • Author

    Pesotchinsky, L.L. ; Fichtenholz, Zinovy

  • Author_Institution
    San Jose State Univ., CA, USA
  • Volume
    1
  • Issue
    1
  • fYear
    1988
  • fDate
    2/1/1988 12:00:00 AM
  • Firstpage
    16
  • Lastpage
    22
  • Abstract
    The two methods examined differ in the procedure used to select wafers for inspection. In the first, or fixed-policy, method, the same number of wafers is inspected regardless of defect density. In the second method a variable policy is used. It is found that in a superclean production environment these inspection methods are not equivalent in defect density estimation: estimates obtained by the variable policy may be biased, while those obtained with the fixed policy are always unbiased. Fundamental reasons for such a phenomenon are discussed and recommendations are made
  • Keywords
    environmental testing; inspection; integrated circuit testing; production testing; biased estimates; defect density estimation; fixed-policy; particle monitoring; semiconductor manufacturing; superclean production environment; unbiased estimates; variable policy; wafer inspection; Automation; Documentation; Fabrication; Inspection; Lithography; Manufacturing processes; Monitoring; Particle production; Semiconductor device manufacture; Testing;
  • fLanguage
    English
  • Journal_Title
    Semiconductor Manufacturing, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0894-6507
  • Type

    jour

  • DOI
    10.1109/66.4368
  • Filename