DocumentCode
957617
Title
The resolution of vertical magneto-resistive readout heads
Author
Davies, A.V. ; Middleton, B.K.
Author_Institution
Data Recording Heads Limited, England
Volume
11
Issue
6
fYear
1975
fDate
11/1/1975 12:00:00 AM
Firstpage
1689
Lastpage
1691
Abstract
Simple formulae have been derived to show the geometrical constraints which determine the resolution of magnetoresistive heads. In the unshielded head the film height is the critical factor which introduces losses which typically reduce the resolution to the order of half the resolution of a conventional inductive head. A shielded MR head has a resolution equivalent to a conventional head having a gap length of between
and
of the shield to shield spacing.
and
of the shield to shield spacing.Keywords
Magnetic recording/reading heads; Magnetoresistive transducers; Coatings; Equations; Geometry; Magnetic films; Magnetic heads; Numerical analysis; Pulse shaping methods; Shape; Space vector pulse width modulation; Voltage;
fLanguage
English
Journal_Title
Magnetics, IEEE Transactions on
Publisher
ieee
ISSN
0018-9464
Type
jour
DOI
10.1109/TMAG.1975.1058969