DocumentCode
958827
Title
Measuring Environmental Corrosivity
Author
Allen, Richard C. ; Trzeciak, Max J.
Author_Institution
IBM Corp., NY
Volume
3
Issue
1
fYear
1980
fDate
3/1/1980 12:00:00 AM
Firstpage
67
Lastpage
70
Abstract
A corrosion indicating bridge (CIB) is proposed as an alternate method to metal coupons for measuring the corrosivity of environments. Six environmental chamber tests were made with corrosion indicating bridges which showed precisions of the CIB´s within a given test exposure ranging from nine percent to 26 percent. Reasons for this variation are given. In addition, the CIB´s were used to compare the six environmental chamber tests which showed an overall precision of abut 30 percent from run to run.
Keywords
Contamination; Environmental measurements; Arm; Bridge circuits; Copper; Corrosion; Electrical resistance measurement; Monitoring; Particle measurements; Petroleum; Pollution measurement; Testing;
fLanguage
English
Journal_Title
Components, Hybrids, and Manufacturing Technology, IEEE Transactions on
Publisher
ieee
ISSN
0148-6411
Type
jour
DOI
10.1109/TCHMT.1980.1135587