The initial permeability μ
ithe loss factor

, and the inverse quality factor

of Fe
5Co
70Si
15B
10ribbons 35μm, 30μm, 25μm and 21μm in thickness were measured with a Maxwell Bridge from room temperature to 140°C in the high-frequency region from 3kHz to 500kHz. The initial permeability of the ribbon 21μm in thickness was about 10,600 at 3kHz and 4300 at 500kHz. The residual loss coefficient C
1and the hysteresis loss coefficient h
1were extremely low, about

and 60(cm/A), respectively. In the high-frequency region, the eddy current loss term increases with the square of the thickness of the ribbons and plays the most important part of all the magnetic losses.