DocumentCode
959435
Title
A simple method for the determination of feedback shift register connections for delayed maximal-length sequences
Author
Yiu, Kai Ping
Author_Institution
Hewlett-Packard Laboratories, Palo Alto, CA
Volume
68
Issue
4
fYear
1980
fDate
4/1/1980 12:00:00 AM
Firstpage
537
Lastpage
538
Abstract
A fast and simple method for computing the feedback shift register connections of a delayed maximal-length sequence is presented. The method is to utilize the modified recurrence relationships repeatedly. This method can be easily programmed on a computer or permits hand computation.