• DocumentCode
    962507
  • Title

    Highly Selective Cyanide Coated-Wire Electrode Based on a Recently Synthesized Co(II) Complex With the N,N -Bis(2-Quinolinecarboxamido)- 1,2-Benzene Applying Batch and Flow Injection Analysis Techniques

  • Author

    Alizadeh, Naader ; Teymourian, Hazhir ; Aghamohammadi, Mohammad ; Meghdadi, Soraia ; Amirnasr, Mehdi

  • Author_Institution
    Tarbiat Modares Univ., Tehran
  • Volume
    7
  • Issue
    12
  • fYear
    2007
  • Firstpage
    1727
  • Lastpage
    1734
  • Abstract
    A poly(vinyl chloride) (PVC)-based coated wire electrode based on [Co(II)bqb] (bqb = N,N´-bis(2-quinolinecarboxamido)-1,2-benzene) as a novel sensing material for determination of trace amounts of cyanide ions is successfully developed. The effect of electrode substrate, membrane composition and pH of the working solution on the behavior of the sensor was investigated. The electrode was also used in flow injection potentiometry by a home-made flow cell. The electrode revealed Nernstian response towards cyanide anion over the concentration ranges 3.2times10-7 to 2.0times10-4 molldrL-1 and 5.0times10-6 to 1.0times10-3 molldrL-1 applying batch and flow injection analysis (FIA), respectively. The lower detection limits are 3.2times10-7 molldrL-1 and 5.0times10-6 molldrL-1 for batch and FIA, respectively. The electrode shows a short response time (<5 s) in the whole concentration range. The selectivity of the electrode in comparison with most of cyanide selective electrodes is high. The flow cell is simple to construct and free from memory effect problems over long periods of use. The proposed electrode was successfully applied for the determination of cyanide in commercially available spring water under both batch and flow injection conditions. A comparative study revealed no significant difference between ASTM method and the proposed technique.
  • Keywords
    chemical variables measurement; electrochemical analysis; electrochemical electrodes; electrochemical sensors; environmental factors; polymer films; water; N,N´-bis(2-quinolinecarboxamido)-1,2-benzene; Nernstian response; batch analysis techniques; cyanide anion concentration; cyanide ion trace determination; flow injection potentiometry; highly selective cyanide coated-wire electrode; home-made flow cell; membrane composition; memory effect problems; pH value; poly(vinyl chloride); response time; sensing material; spring water; Biochemistry; Biomembranes; Chemical industry; Chemical sensors; Chemistry; Delay; Electrodes; Signal analysis; Springs; Wire; Anion sensor; coated wire electrode; cobalt complex; cyanide determination; cyanide ion; flow injection potentiometry;
  • fLanguage
    English
  • Journal_Title
    Sensors Journal, IEEE
  • Publisher
    ieee
  • ISSN
    1530-437X
  • Type

    jour

  • DOI
    10.1109/JSEN.2007.910071
  • Filename
    4375312