• DocumentCode
    962736
  • Title

    Switched-Capacitor Track-and-Hold Amplifiers With Low Sensitivity to Op-Amp Imperfections

  • Author

    Yoshizawa, Hirokazu ; Temes, Gabor C.

  • Author_Institution
    Dept. of Electron. Eng., Saitama Inst. of Technol.
  • Volume
    54
  • Issue
    1
  • fYear
    2007
  • Firstpage
    193
  • Lastpage
    199
  • Abstract
    This paper describes high-precision switched-capacitor (SC) track-and-hold amplifier (THA) stages. They use a novel continuous-time correlated double sampling (CDS) scheme to desensitize the operation to amplifier imperfections. Unlike earlier predictive-CDS amplifiers, the circuits do not need a sampled-and-held input signal for their operation. During the tracking period, an auxiliary continuous-time signal path is established, which predicts the output voltage during the holding period. This allows accurate operation even for low amplifier gains and large offsets over a wide input frequency range. Extensive simulations were performed to compare the performance of the proposed THAs with earlier circuits utilizing CDS. The results verify that their operation is far more robust than that of any previously described SC amplifiers
  • Keywords
    operational amplifiers; sample and hold circuits; switched capacitor networks; analog signal processing; auxiliary continuous-time signal path; continuous-time correlated double sampling scheme; low op-amp imperfection sensitivity; switched-capacitor track-and-hold amplifiers; Circuit noise; Circuit simulation; Clocks; Communication switching; Frequency; Operational amplifiers; Robustness; Sampling methods; Signal processing; Voltage; Analog signal processing; switched-capacitor (SC) amplifier; track-and-hold (T/H) stage;
  • fLanguage
    English
  • Journal_Title
    Circuits and Systems I: Regular Papers, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1549-8328
  • Type

    jour

  • DOI
    10.1109/TCSI.2006.887454
  • Filename
    4061034