DocumentCode :
964107
Title :
Magnetic self-bias in the barber pole MR structure
Author :
Feng, J. S Y ; Romankiw, L.T. ; Thompson, D.A.
Author_Institution :
IBM T.J. Watson Research Center, Yorktown Heights, NY
Volume :
13
Issue :
5
fYear :
1977
fDate :
9/1/1977 12:00:00 AM
Firstpage :
1466
Lastpage :
1468
Abstract :
The Barber Pole structure is shown to have a magnetic bias field produced by the sense current in the shorting bars. This introduces an asymmetry in the magnetic response and aligns the domains in the magnetoresistive sensor.
Keywords :
Magnetic recording/reading heads; Magnetoresistive transducers; Bars; Magnetic analysis; Magnetic anisotropy; Magnetic domains; Magnetic fields; Magnetic materials; Magnetic sensors; Magnetization; Magnetoresistance; Perpendicular magnetic anisotropy;
fLanguage :
English
Journal_Title :
Magnetics, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9464
Type :
jour
DOI :
10.1109/TMAG.1977.1059617
Filename :
1059617
Link To Document :