• DocumentCode
    966012
  • Title

    The effect of third harmonic flux on the core loss in a magnetic frequency multiplier

  • Author

    Lavers, J.D. ; Biringer, P.P.

  • Author_Institution
    University of Toronto, Toronto, Canada
  • Volume
    14
  • Issue
    5
  • fYear
    1978
  • fDate
    9/1/1978 12:00:00 AM
  • Firstpage
    993
  • Lastpage
    995
  • Abstract
    The effect of the load dependent 3rd harmonic flux on the core loss in a magnetic frequency multiplier is examined. The variation of the 3rd harmonic flux (magnitude and phase) with the loading on the multiplier is obtained using an efficient steady state simulation. A recently developed core loss model is then used to determine the effect of the load dependent flux on the losses in the device. On the basis of the harmonic loss model, it is shown that the eddy current losses can be as much as 225% larger than the losses predicted on the basis of peak flux alone.
  • Keywords
    AC-AC power conversion; Magnetic core losses; Power conversion, ac-ac; Circuit faults; Core loss; Eddy currents; Frequency; Magnetic flux; Power harmonic filters; Power system harmonics; Predictive models; Saturation magnetization; Steady-state;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/TMAG.1978.1059798
  • Filename