DocumentCode
966012
Title
The effect of third harmonic flux on the core loss in a magnetic frequency multiplier
Author
Lavers, J.D. ; Biringer, P.P.
Author_Institution
University of Toronto, Toronto, Canada
Volume
14
Issue
5
fYear
1978
fDate
9/1/1978 12:00:00 AM
Firstpage
993
Lastpage
995
Abstract
The effect of the load dependent 3rd harmonic flux on the core loss in a magnetic frequency multiplier is examined. The variation of the 3rd harmonic flux (magnitude and phase) with the loading on the multiplier is obtained using an efficient steady state simulation. A recently developed core loss model is then used to determine the effect of the load dependent flux on the losses in the device. On the basis of the harmonic loss model, it is shown that the eddy current losses can be as much as 225% larger than the losses predicted on the basis of peak flux alone.
Keywords
AC-AC power conversion; Magnetic core losses; Power conversion, ac-ac; Circuit faults; Core loss; Eddy currents; Frequency; Magnetic flux; Power harmonic filters; Power system harmonics; Predictive models; Saturation magnetization; Steady-state;
fLanguage
English
Journal_Title
Magnetics, IEEE Transactions on
Publisher
ieee
ISSN
0018-9464
Type
jour
DOI
10.1109/TMAG.1978.1059798
Filename