Sufficient conditions for ensuring that a continuous stable, proper, minimum-phase plant remains minimum phase when sampled have been derived. As a corollary, the critical sampling frequency (the fastest sampling frequency ensuring minimum-phase behaviour) is shown to satisfy a simple equation. An engineering method to obtain the critical sampling by use of a relay is proposed. This method requires no prior knowledge of the plant
Keywords :
control system analysis; sampled data systems; critical sampling frequency; minimum-phase plant; sampled data systems; sufficient conditions; Cost function; Equations; Frequency; Optimal control; Output feedback; Relays; Sampling methods; State feedback; Sufficient conditions; Transfer functions;