DocumentCode :
968232
Title :
Modelling and state estimation of power plant steam turbines
Author :
Lo, K.L. ; Zeng, P.L. ; Marchand, E. ; Pinkerton, A.
Author_Institution :
Dept. of Electron. & Electr. Eng., Strathclyde Univ., Glasgow, UK
Volume :
137
Issue :
2
fYear :
1990
fDate :
3/1/1990 12:00:00 AM
Firstpage :
80
Lastpage :
94
Abstract :
The development of a robust state estimator for ill-conditioned systems based upon the Levenberg-Marquardt algorithm in connection with Givens orthogonal row processing technique is described. The estimator works in two stages: the square-root-free Givens transformation is applied to the measurement Jacobian matrix to reduce it to the product of a unit upper triangular matrix and a diagonal matrix, then the square-root-free Givens transformation is again used to transform a diagonal matrix whose diagonal element is equal to the Levenberg-Marquardt parameter. The estimator is applied to a 250 MW, double-flow, single reheat steam turbine which has seven feedwater heaters. Tests results show that the estimator performs well under a wide range of measurement errors and measurement redundancy ratios. A sample of estimated results for rated loading condition are presented
Keywords :
state estimation; steam turbines; 250 MW; Givens orthogonal row processing technique; Levenberg-Marquardt algorithm; double-flow; feedwater heaters; ill-conditioned systems; measurement Jacobian matrix; power plant steam turbines; single reheat steam turbine; state estimation;
fLanguage :
English
Journal_Title :
Generation, Transmission and Distribution, IEE Proceedings C