  • Abstract
    The large helical device (LHD) is the world largest helical system having all superconducting coils. After completion of LHD in 1998, six experimental campaigns have been carried out successfully. The maximum stored energy, central electron temperature, and volume averaged beta value are 1.16 MJ, 10 keV, and 3.2%, respectively. The confinement time of the LHD plasma appears to be equivalent to that of tokamaks. One of the most important missions for LHD is to prove steady-state operation, which is also significant to international thermonuclear experimental reactor (ITER) and to future fusion reactors. LHD is quite appropriate for this purpose based upon the beneficial feature of a helical system, that is, no necessity of the plasma current. So far, the plasma discharge duration was achieved up to 150 s. The plasma density was kept constant by feedback control of gas puffing with real time information of the line density. The issue for demonstrating steady-state operation is whether divertor function to control particle and heat flux is effective enough. Relevant to this, LHD diagnostics should be consistent with the following: 1) continuous operation of main diagnostics during long-pulse operation for feedback control and physics understanding; 2) measurement of fraction of H, He, and impurities in the plasma; 3) heat removal and measure against possible damage or surface erosion of diagnostic components inside of the vacuum chamber; 4) data acquisition system for handling real time data display and a huge amount of data. Although there are already some achievements on the above subjects, there remain still several issues to be resolved. On the other hand, the long-pulse operation of the plasma gives benefits to the diagnostics. For example, the polarizing angle of ECE emission can be changed during the discharge, and the intensity dependence on the polarizing angle has been obtained. The spatial scanning of the neutral particle analyzer and the spectrometer can supply the spatial profiles of the fast neutral particle flux and the specific impurity lines. In this paper, the present status of these issues and future plans are described.
  • Keywords
    discharges (electric); fusion reactor design; plasma density; plasma diagnostics; plasma impurities; plasma instability; plasma temperature; plasma toroidal confinement; stellarators; ECE emission; LHD diagnostics; central electron temperature; fusion reactor; gas puffing feedback control; international thermonuclear experimental reactor; large helical device; line density; long-pulse operation; maximum stored energy; neutral particle analyzer; plasma confinement; plasma density; plasma discharge duration; real time information; steady-state operation; superconducting coil; volume averaged beta value; Feedback control; Impurities; Plasma confinement; Plasma density; Plasma diagnostics; Plasma displays; Plasma measurements; Plasma temperature; Polarization; Steady-state;
  • fLanguage
    English
  • Journal_Title
    Plasma Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-3813
  • Type

    jour

  • DOI
    10.1109/TPS.2004.823896
  • Filename
    1291617