DocumentCode :
969328
Title :
Tomographic reconstruction of power density in electron beams used for machining
Author :
Kirner, F.K.
Author_Institution :
Institut fuer Allgemeine ET and Elektronik, Wien, Austria
Volume :
71
Issue :
6
fYear :
1983
fDate :
6/1/1983 12:00:00 AM
Firstpage :
781
Lastpage :
782
Abstract :
This letter describes a new method to measure the spatial distribution of the power density in electron beams. At various angles, the projections of the current density are taken by scanning the beam with a straight edge. The spatial distribution is reconstructed by using the "Convoluted Backprojection." The resolution obtained is about 3 percent.
Keywords :
Current density; Current measurement; Density measurement; Electrodes; Electron beams; Machining; Power measurement; Probes; Shape measurement; Tomography;
fLanguage :
English
Journal_Title :
Proceedings of the IEEE
Publisher :
ieee
ISSN :
0018-9219
Type :
jour
DOI :
10.1109/PROC.1983.12672
Filename :
1456940
Link To Document :
بازگشت