DocumentCode :
969933
Title :
Suction vs. Pressure Forced Air Cooling
Author :
Rezek, Gerard
Volume :
9
Issue :
1
fYear :
1965
fDate :
4/1/1965 12:00:00 AM
Firstpage :
30
Lastpage :
35
Abstract :
The cooling of miniaturized equipment is usually handled by forced air flow. An investigation was made of the merits of suction vs pressure cooling, to find an effective cooling design for a certain module assembly. This showed that suction cooling has certain advantages because of the air flow escape from the circuitry section to adjacent spaces. Its air flow pattern provides maximum air accretion at the air exit, which is a critical area. That suction cooling will minimize air temperatures in that area is qualitatively developed and then quantitatively analyzed.
Keywords :
Assembly; Circuits; Electronic equipment; Electronics cooling; Insulation; Linearity; Modular construction; Pattern analysis; Space cooling; Temperature;
fLanguage :
English
Journal_Title :
Product Engineering and Production, IEEE Transactions on
Publisher :
ieee
ISSN :
0097-4544
Type :
jour
DOI :
10.1109/TPEP.1965.1136694
Filename :
1136694
Link To Document :