DocumentCode :
971519
Title :
A Correlation Study Between Geometry of Collared Coils and Normal Quadrupole Multipole in the Main LHC Dipoles
Author :
Bertinelli, F. ; Boter-Rebollo, E. ; Berthollon-Vitte, S. ; Glaude, D. ; Vanenkov, I.
Author_Institution :
CERN, Geneva
Volume :
16
Issue :
2
fYear :
2006
fDate :
6/1/2006 12:00:00 AM
Firstpage :
192
Lastpage :
195
Abstract :
The quality control implemented at all LHC dipole assemblers includes precise mechanical measurements of the geometry of collared coils. A cross-analysis performed between mechanical and magnetic measurements data shows a correlation between collared coils outer dimensions and the normal quadrupole multipole (b2) for one dipole assembler. The profile geometry of the single collars-as determined from 3D measurements at the collar suppliers and CERN-could not account alone for the significant left-right aperture asymmetry observed. This triggered a deeper investigation on different elements of the geometry of single collars. The results of this work show that the relative positioning of the collaring holes, allowing a small bending deformation of collars under the effect of coil pre-stress, is an important effect that generates a b2 multipole at the limit of specification. The study has deepened the understanding of the factors affecting collared coil geometry and field quality. The precision of 3D measurements at the collar suppliers and at CERN has been improved, and a tighter quality control has been introduced at the collar suppliers
Keywords :
accelerator magnets; austenitic steel; geometry; ion accelerators; proton accelerators; storage rings; superconducting coils; superconducting magnets; synchrotrons; 3D measurements; CERN; austenitic-steel collars; collared coils; correlation study; left-right aperture asymmetry; magnetic field quality; main LHC dipoles; mechanical measurements; normal quadrupole multipole; profile geometry; quality control; small bending deformation; superconducting magnets; warm magnetic measurements; Apertures; Assembly; Coils; Geometry; Large Hadron Collider; Magnetic field measurement; Magnetic variables measurement; Mechanical variables measurement; Performance evaluation; Quality control; Austenitic-steel collars; magnetic field quality; superconducting magnets; warm magnetic measurements;
fLanguage :
English
Journal_Title :
Applied Superconductivity, IEEE Transactions on
Publisher :
ieee
ISSN :
1051-8223
Type :
jour
DOI :
10.1109/TASC.2006.870498