• DocumentCode
    972302
  • Title

    Test of Peltier Current Lead for Cryogen-Free Superconducting Magnet

  • Author

    Hamabe, M. ; Sasaki, A. ; Kasukabe, T. ; Oue, M. ; Nakamura, K. ; Yamaguchi, S. ; Ninomiya, A. ; Okumura, H. ; Kawamura, K. ; Aoki, I.

  • Author_Institution
    Chubu Univ., Kasugai
  • Volume
    16
  • Issue
    2
  • fYear
    2006
  • fDate
    6/1/2006 12:00:00 AM
  • Firstpage
    465
  • Lastpage
    468
  • Abstract
    Peltier current leads (PCL) were applied to a cryogen-free superconducting magnet (CFM) of 5 T/90 A. We measured the temperature profiles on the current lead of the CFM. Compared with the conventional copper current lead, the PCL reduced the temperature and the temperature gradient on the first stage of the cryocooler of the CFM at zero current. The current operation of the CFM improved the reductions due to the heat pump of the Peltier element. These results are the direct proof of the heat leakage reduction by the PCL
  • Keywords
    Peltier effect; cryogenics; superconducting magnets; Peltier current lead; cryocooler; cryogen-free superconducting magnet; cryogenics; heat leakage reduction; thermoelectric devices; Copper; Cryogenics; Current measurement; Heat pumps; High temperature superconductors; Superconducting magnets; Temperature measurement; Testing; Thermal conductivity; Thermoelectric devices; Cryogenics; superconducting magnets; thermoelectric devices;
  • fLanguage
    English
  • Journal_Title
    Applied Superconductivity, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1051-8223
  • Type

    jour

  • DOI
    10.1109/TASC.2006.873326
  • Filename
    1642888