  • Abstract
    An effective and unique method of measuring independently the variations of resistive and capacitive constituents of a practical capacitive transducer using an improved pseudo-active bridge is described. The impedance change in some types of transducers may be due to changes in resistance and/or capacitance either way. Separation of changes in resistance and capacitance results in a better understanding of the transduced variable. The active bridge which separates the changes is suitable for online determination of the two changes.
  • Keywords
    active networks; bridge circuits; bridge instruments; capacitance measurement; electric resistance measurement; transducers; capacitance measurement; capactive/conductive transducer; pseudoactive bridge; resistance measurement;