DocumentCode
973399
Title
Pseudoactive bridge for separation of R and C in a practical capacitive/conductive transducer
Author
Padmanabhan, K. ; Sarma, G.S. Somayajulu
Author_Institution
University of Madras, Central Instrumentation and Services Laboratory, Indian Institute of Technology, Madras, India
Volume
17
Issue
19
fYear
1981
Firstpage
705
Lastpage
706
Abstract
An effective and unique method of measuring independently the variations of resistive and capacitive constituents of a practical capacitive transducer using an improved pseudo-active bridge is described. The impedance change in some types of transducers may be due to changes in resistance and/or capacitance either way. Separation of changes in resistance and capacitance results in a better understanding of the transduced variable. The active bridge which separates the changes is suitable for online determination of the two changes.
Keywords
active networks; bridge circuits; bridge instruments; capacitance measurement; electric resistance measurement; transducers; capacitance measurement; capactive/conductive transducer; pseudoactive bridge; resistance measurement;
fLanguage
English
Journal_Title
Electronics Letters
Publisher
iet
ISSN
0013-5194
Type
jour
DOI
10.1049/el:19810494
Filename
4245972
Link To Document