Title :
Powering Multi-Coil Systems Combining DC and Pulsed Power Supplies
Author :
Perenboom, J.A.A.J. ; Rosseel, K. ; Dolron, P.A.J. ; Wiegers, S.A.J. ; Frings, P.H. ; Maan, J.C.
Author_Institution :
Nijmegen Univ.
fDate :
6/1/2006 12:00:00 AM
Abstract :
The highest non-destructive fields are provided by pulsed field magnets. Monolithic coils are limited to 70-75 Tesla by mechanical and thermal constraints. These limitations can be circumvented through the use of multi-coil assemblies. At HFML, pulsed field magnets can be energized using either a 2 MJ, 16 kV capacitor bank or a state-of-the-art 20 MW DC power supply in pulsed mode; each of these sources is capable of delivering up to 20 kA. This would allow multi-coil operation at fields to above 80 T
Keywords :
capacitors; coils; fault diagnosis; magnetic fields; pulsed power supplies; 16 kV; 20 MW; 20 kA; DC power supply; capacitor bank; fault diagnosis; monolithic coil; multicoil system; power control; pulse generation; pulsed field magnet; pulsed power supply; Capacitors; Circuit testing; Coils; Heating; Laboratories; Magnetic fields; Magnetic materials; Magnets; Pulsed power supplies; Voltage; Fault diagnosis; magnetic fields; power control; pulse generation;
Journal_Title :
Applied Superconductivity, IEEE Transactions on
DOI :
10.1109/TASC.2005.864283