DocumentCode :
975897
Title :
Coercivity measurements on high permeability nickel-iron alloys using a modified NPL vibrating coil magnetometer
Author :
Drake, A.E. ; Jasko, T.M.
Author_Institution :
Nat. Phys. Lab., Teddington, UK
Volume :
143
Issue :
3
fYear :
1996
fDate :
5/1/1996 12:00:00 AM
Firstpage :
171
Lastpage :
172
Abstract :
A method for the rapid measurement of low coercive force materials (e.g. high permeability nickel iron alloys) has developed by modifying the NPL vibrating coil magnetometer to improve its sensitivity and by providing a magnetic shield to reduce the effects of the ambient magnetic field. A comparison of the results has been made with those obtained by the traditional ring method
Keywords :
coercive force; ferroelectric materials; iron alloys; magnetic shielding; magnetic variables measurement; magnetometers; nickel alloys; sensitivity; soft magnetic materials; Ni-Fe; ambient magnetic field effects; coercivity measurement; high permeability alloys; improved sensitivity; low coercive force materials; magnetic shield; modified NPL vibrating coil magnetometer; rapid measurement; soft magnetic materials;
fLanguage :
English
Journal_Title :
Science, Measurement and Technology, IEE Proceedings -
Publisher :
iet
ISSN :
1350-2344
Type :
jour
DOI :
10.1049/ip-smt:19960309
Filename :
502434
Link To Document :