DocumentCode
977555
Title
Data partitioning in parametric harmonic analysis
Author
Nguyen, T.T.
Author_Institution
Energy Syst. Centre, Western Australia Univ., Nedlands, WA, Australia
Volume
32
Issue
13
fYear
1996
fDate
6/20/1996 12:00:00 AM
Firstpage
1160
Lastpage
1161
Abstract
The key feature of the advance in parametric harmonic analysis reported that of partitioning the data series into a training set and a test set. Test errors are monitored in successive training error minimisations. The analysis procedure achieves high resolution between frequency components, and minimises the data window required in harmonic analysis
Keywords
data handling; error analysis; harmonic analysis; identification; minimisation; signal processing; spectral analysis; data partitioning; data series; parametric harmonic analysis; test errors monitoring; test set; training error minimisations; training set;
fLanguage
English
Journal_Title
Electronics Letters
Publisher
iet
ISSN
0013-5194
Type
jour
DOI
10.1049/el:19960784
Filename
502975
Link To Document