Title :
Matching using double slug transformer and correction to transistor gain
Author :
Twisleton, J.R.G.
Author_Institution :
EEV Co. Ltd., Lincoln, UK
fDate :
6/1/1989 12:00:00 AM
Abstract :
Matching using a coaxial double slug transformer, particularly in relation to measurements on microwave transistors at 0.5-2 GHz, is described. The limits arising from tuner loss and the correction to transistor gain which needs to be applied are determined analytically. The correction is compared with that deduced from reflection measurements, good agreement being obtained. The use of parallel plate line is investigated and from its Q-factor is shown to be a possible lower loss alternative to coaxial line in this application, provided that small radiation effects can be suppressed.<>
Keywords :
impedance matching; microwave devices; transformers; transmission line theory; 0.25 to 2 GHz; Q-factor; coaxial double slug transformer; correction; impedance matching; measurements; microwave transistors; parallel plate line; transistor gain; tuner loss; Impedance matching; Microwave devices; Transformers; Transmission line theory;
Journal_Title :
Microwaves, Antennas and Propagation, IEE Proceedings H