DocumentCode :
979399
Title :
An improved method of measuring power-line impedances using two current probes
Author :
Kwasniok, Peter J. ; Kozlowski, A. James ; Stuchly, Stanislaw S.
Author_Institution :
Mosaid Technol. Inc., Kanata, Ont., Canada
Volume :
35
Issue :
4
fYear :
1993
fDate :
11/1/1993 12:00:00 AM
Firstpage :
473
Lastpage :
475
Abstract :
A modified calibration model for the two current probe method of measuring power-line impedances which extends the use of this method up to 500 MHz is presented. The model is based on a generalized S-parameter equivalent circuit of the measurement system. Experimental verification of the accuracy of the model is given
Keywords :
S-parameters; calibration; electric impedance measurement; equivalent circuits; power transmission lines; probes; 100 to 1000 MHz; generalized S-parameter equivalent circuit; modified calibration model; power line impedance measurement; two current probe method; Calibration; Circuits; Current measurement; Electromagnetic measurements; Electrostatic measurements; Frequency measurement; Impedance measurement; Power system modeling; Probes; Voltage;
fLanguage :
English
Journal_Title :
Electromagnetic Compatibility, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9375
Type :
jour
DOI :
10.1109/15.247864
Filename :
247864
Link To Document :
بازگشت