Influence of Resistance of Electric Arc on Transients Due to Disconnector Switching in Air-Insulated Substations
Author
Carsimamovic, Salih ; Bajramovic, Zijad ; Veledar, Meludin ; Ljevak, Miroslav ; Carsimamovic, Adnan ; Osmokrovic, Predrag
Author_Institution
Fac. of Electr. Eng., Univ. of Sarajevo, Sarajevo
Volume
36
Issue
5
fYear
2008
Firstpage
2560
Lastpage
2565
Abstract
In this paper, switching overvoltages due to disconnector switching in air-insulated substations (AISs) are presented. Measurements of these switching overvoltages were performed in the AIS Grabovica (Hydro Power Plant-HPP Grabovica) on River Neretva and the AIS Kakanj (Thermo Power Plant-TPP Kakanj). These power plants are important objects for operation of Bosnia and Herzegovina´s electric power system. Investigations of operating of air-disconnector-type centre break was performed in order to determine switching-overvoltage levels on primary and secondary circuits that can lead to relay tripping in AIS Grabovica and AIS Kakanj. During operations of disconnector (synchronization or disconnecting of generator from network), malfunctions of signaling devices and burning of supply units of protection relays appeared. At the same time, sparking between primary terminals of the instrument current transformer occurred. The influence of resistance of electric arc between the contacts of the disconnector is analyzed. Computer simulations by means of alternative transients program-electromagnetic transients program are performed. Differences between the measured and the calculated values were under 4.52% for overvoltage factor and under 2.56% for overvoltage wave frequency. Comparison of the transient computer simulations with the field measurements showed that calculations could be used for the assessment of the transient overvoltages caused by disconnector switching.
Keywords
air insulation; arcs (electric); electric resistance; overvoltage protection; relay protection; substation protection; switching substations; switching transients; AIS; AIS Grabovica; AIS Kakanj; Bosnia electric power system; Herzegovina´s electric power system; air-insulated substations; alternative transients program-electromagnetic transients program; disconnector switching; electric arc resistance; field measurements; hydro power plant; instrument current transformer; relay protection; relay tripping; signaling device malfunction; switching overvoltages; thermo power plant; transients; Air insulation; arc discharges; overvoltage protection; transient response;
fLanguage
English
Journal_Title
Plasma Science, IEEE Transactions on
Publisher
ieee
ISSN
0093-3813
Type
jour
DOI
10.1109/TPS.2008.2004238
Filename
4667684
Link To Document