• DocumentCode
    981302
  • Title

    Limit cycles in relay systems

  • Author

    Atherton, Derek P.

  • Author_Institution
    University of Sussex, School of Engineering & Applied Sciences, Brighton, UK
  • Volume
    18
  • Issue
    21
  • fYear
    1982
  • Firstpage
    922
  • Lastpage
    923
  • Abstract
    A method using the z transform is presented for evaluating the frequency of limit cycles in relay systems. The technique as described is only applicable when the relay has no dead zone and the plant transfer function no time delay. An extension of the approach to these systems is possible but requires use of the modified z transform; this makes the calculations more cumbersome and the method loses its simplicity.
  • Keywords
    Z transforms; limit cycles; relay control; transfer functions; limit cycles; relay control; relay systems; transfer function; z transform;