DocumentCode
982075
Title
DESC field failure evaluation program-´a cradle to grave approach´
Author
Lantz, Bradley A. ; McNicholl, Brian P.
Author_Institution
Defense Electronics Supply Center, Dayton, OH, USA
Volume
8
Issue
8
fYear
1993
Firstpage
22
Lastpage
25
Abstract
The Defense Electronics Supply Center´s (DESC´s) field failure evaluation program is described. The primary objective of the program is to take positive corrective action steps to assure that quality electronics parts are used in US Department of Defense (DoD) weapon systems. The process flow of field failures from their inception to final corrective action is discussed. To illustrate this, four case studies are presented in which lab testing and coordination with the supplier has resulted in positive corrective action, improving the quality and reliability of the electronic components in DoD weapon systems.<>
Keywords
electronic equipment testing; failure analysis; quality control; reliability; weapons; DoD; US Department of Defense; amplifier electron tubes; dynamic microphone; field failure evaluation; lighting switch; quality electronics parts; reliability; variable air dielectric capacitors; weapon; Electronic components; Electronic equipment testing; Failure analysis; Feedback loop; Personnel; Process control; Quality assurance; System testing; Weapons; Writing;
fLanguage
English
Journal_Title
Aerospace and Electronic Systems Magazine, IEEE
Publisher
ieee
ISSN
0885-8985
Type
jour
DOI
10.1109/62.248330
Filename
248330
Link To Document