• DocumentCode
    982075
  • Title

    DESC field failure evaluation program-´a cradle to grave approach´

  • Author

    Lantz, Bradley A. ; McNicholl, Brian P.

  • Author_Institution
    Defense Electronics Supply Center, Dayton, OH, USA
  • Volume
    8
  • Issue
    8
  • fYear
    1993
  • Firstpage
    22
  • Lastpage
    25
  • Abstract
    The Defense Electronics Supply Center´s (DESC´s) field failure evaluation program is described. The primary objective of the program is to take positive corrective action steps to assure that quality electronics parts are used in US Department of Defense (DoD) weapon systems. The process flow of field failures from their inception to final corrective action is discussed. To illustrate this, four case studies are presented in which lab testing and coordination with the supplier has resulted in positive corrective action, improving the quality and reliability of the electronic components in DoD weapon systems.<>
  • Keywords
    electronic equipment testing; failure analysis; quality control; reliability; weapons; DoD; US Department of Defense; amplifier electron tubes; dynamic microphone; field failure evaluation; lighting switch; quality electronics parts; reliability; variable air dielectric capacitors; weapon; Electronic components; Electronic equipment testing; Failure analysis; Feedback loop; Personnel; Process control; Quality assurance; System testing; Weapons; Writing;
  • fLanguage
    English
  • Journal_Title
    Aerospace and Electronic Systems Magazine, IEEE
  • Publisher
    ieee
  • ISSN
    0885-8985
  • Type

    jour

  • DOI
    10.1109/62.248330
  • Filename
    248330