• DocumentCode
    982741
  • Title

    Disposable PVDF ultrasonic transducers for nondestructive testing applications

  • Author

    Brown, Lewis F. ; Mason, Joel L.

  • Author_Institution
    Dept. of Electr. Eng., South Dakota State Univ., Brookings, SD, USA
  • Volume
    43
  • Issue
    4
  • fYear
    1996
  • fDate
    7/1/1996 12:00:00 AM
  • Firstpage
    560
  • Lastpage
    568
  • Abstract
    Disposable ultrasonic contact transducers have been constructed with inexpensive PVDF films for nondestructive testing (NDT) applications. This paper reports the temperature-dependent ultrasonic performance of commercial polyvinylidene fluoride (PVDF) films and PVDF sensors. PVDF film was evaluated for its material properties of interest for ultrasonic transducer performance including the relative dielectric constant /spl epsi//sub r/, dielectric loss tangent tan /spl delta//sub e/, electromechanical coupling constant k/sub t/, mechanical quality factor Q/sub m/, and acoustic impedance Z. Disposable PVDF transducers were then coupled to both low and high acoustic impedance test panels and their ultrasonic insertion loss/sensitivity and frequency bandwidth measured as a function of temperature in both the pulse-echo and pitch-catch modes. The results yielded center frequencies in the 3.5-16 MHz range, with -6-dB fractional bandwidths for some of the transducers exceeding 100%. The temperature dependence of the transducers´ performance is reported for the -40 to 80/spl deg/C range and shows an approximate linear decrease in center frequency and increase in fractional bandwidth with increasing temperature. These measured results are compared with predictions from computer simulations based on Mason´s model. These tests showed that the same disposable transducers can be used for both ultrasonic and acoustic emission sensing NDT applications. This paper summarizes the quantitative ultrasonic and vibration sensing performance for all of the disposable PVDF film transducers which were tested.
  • Keywords
    acoustic emission testing; acoustic impedance; dielectric losses; echo; permittivity; polymer films; ultrasonic materials testing; ultrasonic transducers; -40 to 80 degC; 3.5 to 16 MHz; Mason´s model; PVDF ultrasonic transducers; acoustic emission sensing; acoustic impedance; center frequency; dielectric loss tangent; electromechanical coupling constant; fractional bandwidths; frequency bandwidth; insertion loss; mechanical quality factor; nondestructive testing; pitch-catch mode; polyvinylidene fluoride; pulse-echo mode; relative dielectric constant; temperature-dependent ultrasonic performance; ultrasonic emission sensing; Acoustic pulses; Acoustic testing; Acoustic transducers; Bandwidth; Dielectric loss measurement; Frequency; Impedance; Nondestructive testing; Temperature sensors; Ultrasonic transducers;
  • fLanguage
    English
  • Journal_Title
    Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-3010
  • Type

    jour

  • DOI
    10.1109/58.503716
  • Filename
    503716