Title :
Direct-drive induction motors: using an induction motor as an alternative to a motor with reducer
Author :
Evon, Steve ; Schiferl, Rich
Author_Institution :
Rockwell Autom., Greenville, SC, USA
Abstract :
This article presents the performance and size comparisons of direct-drive induction motors with gearbox-driven systems. Three different low-speed applications with output speeds to the driven equipment ranging from 300-600 r/min is reviewed. In addition, permanent-magnet (PM) motor advantages and disadvantages are also discussed.
Keywords :
induction motor drives; permanent magnet motors; variable speed drives; direct-drive induction motor; gearbox-driven system; permanent-magnet motor; variable speed application; AC motors; Brushes; Commutation; Costs; DC motors; Induction motors; Maintenance; Paper making machines; Rotors; Stators;
Journal_Title :
Industry Applications Magazine, IEEE
DOI :