DocumentCode :
983176
Title :
Improving the traceability of coaxial impedance measurements at lower RF in the UK
Author :
Ridler, N.M. ; Medley, J.C.
Volume :
143
Issue :
4
fYear :
1996
fDate :
7/1/1996 12:00:00 AM
Firstpage :
241
Lastpage :
246
Abstract :
The authors report on a measurement service introduced recently by NPL at Malvern to provide traceability for impedance, and other complex reflection parameters, for coaxial line terminations fitted with APC-7 connectors at frequencies below 50 MHz. The new service is a result of several improvements made to an existing measurement system. These improvements, including the use of robust statistical techniques to reduce the uncertainty of measurement, are discussed and typical results produced by the enhanced system are presented
Keywords :
calibration; coaxial cables; electric connectors; electric impedance measurement; electromagnetic wave reflection; measurement standards; statistical analysis; 100 kHz to 50 MHz; APC-7 connectors; NPL; coaxial impedance measurements; coaxial line terminations; complex reflection parameters; low frequency calibration; lower RF range; measurement service; measurement uncertainty; robust statistical techniques; traceability;
fLanguage :
English
Journal_Title :
Science, Measurement and Technology, IEE Proceedings -
Publisher :
iet
ISSN :
1350-2344
Type :
jour
DOI :
10.1049/ip-smt:19960524
Filename :
503751
Link To Document :
بازگشت