• DocumentCode
    983519
  • Title

    A Low-Noise X-Band Radiometer Using Maser

  • Author

    Cook, J.J. ; Cross, L.G. ; Bair, M.E. ; Terhune, R.W.

  • Author_Institution
    Willow Run Labs., University of Mich., Ann Arbor
  • Volume
    49
  • Issue
    4
  • fYear
    1961
  • fDate
    4/1/1961 12:00:00 AM
  • Firstpage
    768
  • Lastpage
    778
  • Abstract
    A low-noise X-band radiometer, using a ruby maser preamplifier in radio astronomy measurements, is discussed. The radiometer uses a reflection-cavity maser with voltage-gain bndwidth products as high as 300 Mc at 4.2°K. Less than 1 per cent short-term gain instability and dependable performance are obtained. A system noise factor (excluding antenna spillover) of 0.6 db 43°K) has been obtained. The system bandwidth is limited to 8 Mc by the intermediate frequency bandwidth, with maser bandwidths of 20-30 Mc available. RMS noise fluctuations of approximately 0.01°K with a 12-second integration time and 0.007°K with a 42-second integration time are obtained. Gain instability of 0.6 per cent up to 10 minutes and 2 per cent up to 30 minutes has been measured. Electrical and mechanical features as well as measurement and operational techniques are described. Performance data and radio astronomy observations are discussed.
  • Keywords
    Antenna measurements; Bandwidth; Extraterrestrial measurements; Frequency; Masers; Performance gain; Preamplifiers; Radio astronomy; Radiometry; Voltage;