• DocumentCode
    984770
  • Title

    Partial discharge measurements in dielectric liquids under impulse voltage

  • Author

    Yamashita, Hisanao

  • Author_Institution
    Keio Univ., Yokohama, Japan
  • Volume
    28
  • Issue
    6
  • fYear
    1993
  • fDate
    12/1/1993 12:00:00 AM
  • Firstpage
    947
  • Lastpage
    955
  • Abstract
    Current pulses caused by partial discharges (PDs) are measured using light-emitting diodes (LEDs) and fiber optics under impulse voltage conditions. This system has the advantage of having good isolation from the HV power supply and no effect from electromagnetic noise as compared with ordinary systems. It can detect a PD pulse having a half width of 3 ns, and has the capability of measuring PD pulse charges in the range of 1 to 2000 pC, when the optimum DC bias is applied. PD pulses and light emission or streamer formation in dielectric liquids are measured simultaneously by using an image converter camera
  • Keywords
    electric breakdown of liquids; electric current measurement; fibre optic sensors; light emitting diodes; optical variables measurement; partial discharges; 3 ns; HV power supply isolation; LEDs; PD pulse charges; current pulses; dielectric liquids; fiber optics; image converter camera; impulse voltage; light-emitting diodes; optimum DC bias; partial discharge measurements; streamer formation; Current measurement; Dielectric liquids; Dielectric measurements; Electromagnetic measurements; Light emitting diodes; Optical pulses; Partial discharge measurement; Partial discharges; Pulse measurements; Pulsed power supplies;
  • fLanguage
    English
  • Journal_Title
    Electrical Insulation, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9367
  • Type

    jour

  • DOI
    10.1109/14.249368
  • Filename
    249368