DocumentCode
984801
Title
Computer-aided measurement of partial discharges in HV equipment
Author
Gulski, E.
Author_Institution
Dept. of Electr. Eng., Delft Univ. of Technol., Netherlands
Volume
28
Issue
6
fYear
1993
fDate
12/1/1993 12:00:00 AM
Firstpage
969
Lastpage
983
Abstract
A previously developed method of partial discharge (PD) recognition is used to evaluate PD in HV devices. Using conventional discharge detection (bandwidth ~400 kHz), the PD patterns are studied. By means of unambiguous statistical operators like skewness, kurtosis, number of peaks, etc., quantitative information about the discharge source can be obtained. In the case of an unknown defect, a combination of these operators is compared to the same set of operators for a known configuration. In this way, a statement can be made on the character of a discharge source. The use of this technique in evaluating different discharges in HV cable and in 400 kV SF6 insulation confirms the usefulness of the new approach
Keywords
automatic test equipment; cable testing; electric variables measurement; high-voltage techniques; insulation testing; partial discharges; pattern recognition; statistical analysis; 400 kHz; 400 kV; HV cable; HV equipment; PD measurement; PD patterns; PD recognition; SF6; SF6 insulation; computer-aided measurement; discharge source; partial discharges; statistical operators; Automatic testing; Bandwidth; Cable insulation; Dielectrics and electrical insulation; Fault location; Laboratories; Partial discharges; Pattern recognition; Shape; System testing;
fLanguage
English
Journal_Title
Electrical Insulation, IEEE Transactions on
Publisher
ieee
ISSN
0018-9367
Type
jour
DOI
10.1109/14.249370
Filename
249370