DocumentCode :
984813
Title :
Coupler Winding Ratio Selection for Effective Narrowband Power-Line Communications
Author :
Van Rensburg, Petrus A Janse ; Ferreira, Hendrik C.
Author_Institution :
Walter Sisulu Univ., East London
Volume :
23
Issue :
1
fYear :
2008
Firstpage :
140
Lastpage :
149
Abstract :
Coupling losses caused by impedance mismatches are often underestimated and neglected by power-line communications researchers and manufacturers. Further, the variations in network topology combined with unknown cable and load impedances obscure the requirements for impedance adaptation, causing researchers and manufacturers to default to a guessed impedance level and a fixed winding ratio. Attempting to clarify said requirements, this paper approaches the transmitter-to-receiver chain using a simplified lumped-parameter model, which distinguishes between the influences of series (cable) and parallel (load) power-line impedances. Using apparent power transfer to the receiver as criterion, the influence of both the transmitter and receiver coupler winding ratios are investigated for 50- modems at frequencies below 1 MHz. Live measurements indicate that the results are useful regardless of power-line topology, yielding gains up to 10 dB.
Keywords :
carrier transmission on power lines; impedance matching; apparent power transfer; coupler winding ratio selection; coupling circuits; impedance matching; lumped-parameter model; modems; narrowband power-line communications; network topology; power-line impedances; transformers; transmitter-to-receiver chain; Africa; Coupling circuits; Frequency; Impedance matching; Manufacturing; Modems; Narrowband; Network topology; Transformers; Transmitters; Coupling circuits; filters; impedance matching; modems; transformers;
fLanguage :
English
Journal_Title :
Power Delivery, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-8977
Type :
jour
DOI :
10.1109/TPWRD.2007.905790
Filename :
4385726
Link To Document :