• DocumentCode
    984848
  • Title

    Digital correction of A/D conversion error due to multiplexing delay

  • Author

    Barwicz, Andrzej ; Bellemare, Daniel ; Morawski, Roman Z.

  • Author_Institution
    Dept. d´´Ingenierie, Quebec Univ., Trois-Rivieres, Que., Canada
  • Volume
    39
  • Issue
    1
  • fYear
    1990
  • fDate
    2/1/1990 12:00:00 AM
  • Firstpage
    76
  • Lastpage
    79
  • Abstract
    A measurement channel which consists of a multiplexer, sample-and-hold circuit, and analog-to-digital (A/D) converter is studied. It is designed for the synchronous sampling and measurement of two or more voltage signals V1(t), V 2(t), . . ., but the finite time of A/D conversion (ΔT) makes it impossible to acquire consecutive samples closer in time than ΔT. This can become a source of measurement error if further processing of the measurement data is based on the assumption of ideal synchronism. It has been found that interpolation filters, developed from the Lagrange polynomial interpolation, are useful tools for solving the problem of correction. An illustrative example of their use is presented
  • Keywords
    analogue-digital conversion; error analysis; error correction; interpolation; measurement errors; multiplexing; polynomials; signal processing equipment; voltage measurement; A/D conversion error; Lagrange polynomial interpolation; digital correction; interpolation filters; measurement error; multiplexing delay; synchronous sampling; voltage signals; Analog-digital conversion; Circuits; Error correction; Filters; Interpolation; Measurement errors; Multiplexing; Sampling methods; Signal design; Voltage;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/19.50420
  • Filename
    50420