DocumentCode :
985112
Title :
Improvements to an electromagnetic near-field sensor for simultaneous electric and magnetic field measurement
Author :
Upton, Miles E G ; Marvin, Andrew C.
Author_Institution :
Dept. of Electron., York Univ., UK
Volume :
35
Issue :
1
fYear :
1993
fDate :
2/1/1993 12:00:00 AM
Firstpage :
96
Lastpage :
98
Abstract :
A sensor for simultaneous electric and magnetic field measurement has been described by M. Kanda (see ibid., vol.EMC-26, no.3, p.102-10, 1984). It relies upon measuring the voltage across precisely matched loads at opposite sides of a loop antenna. A modification to the theory is presented to account for unmatched loading of the loop. Measured results of wave impedance over a 10-400-MHz range demonstrate the accuracy of the modified theory as well as highlighting a novel calibration technique
Keywords :
electric field measurement; electromagnetic fields; loop antennas; magnetic field measurement; calibration technique; electric field measurement; electromagnetic near-field sensor; loop antenna; magnetic field measurement; unmatched loading; wave impedance; Admittance; Electric variables measurement; Electromagnetic fields; Electromagnetic measurements; Equations; Impedance measurement; Magnetic field measurement; Magnetic sensors; Sensor phenomena and characterization; Voltage;
fLanguage :
English
Journal_Title :
Electromagnetic Compatibility, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9375
Type :
jour
DOI :
10.1109/15.249402
Filename :
249402
Link To Document :
بازگشت