DocumentCode
985575
Title
Transient 3D eddy currents using modified magnetic vector potentials and magnetic scalar potentials
Author
Emson, C.R.I. ; Trowbridge, C.W.
Author_Institution
Rutherford Appleton Lab., Chilton, UK
Volume
24
Issue
1
fYear
1988
fDate
1/1/1988 12:00:00 AM
Firstpage
86
Lastpage
89
Abstract
A package named VECTOR for solving 3-D eddy current problems is presented. The package is a developmental version of the commercial package CARMEN and in the same way solves the vector diffusion equation, involving a modified vector potential, within conductors and the scalar Poisson equation, using a magnetic scalar potential, in non-eddy-current regions. It has been shown that this set of equations yields a unique solution for both the magnetic vector potential (and hence the currents) and the fields (which are derived from the magnetic potentials by differentiation). This package has recently been extended to solve transient problems, using simple time-stepping techniques. Some results using the package for problems with analytic solutions are given
Keywords
eddy currents; CARMEN; VECTOR; conductors; magnetic scalar potentials; modified magnetic vector potentials; scalar Poisson equation; time-stepping techniques; transient 3D eddy currents; vector diffusion equation; Conductivity; Conductors; Differential equations; Eddy currents; Electric potential; Laboratories; Magnetic materials; Packaging; Poisson equations; Symmetric matrices;