Title :
Matrices for selective diamagnetic HGMS
Author :
Takayasu, M. ; Friedlaender, F.J. ; Hiresaki, Y. ; Kelland, D.R.
Author_Institution :
Purdue University, West Lafayette, Indiana, USA.
fDate :
11/1/1981 12:00:00 AM
Abstract :
Both the diamagnetic and paramagnetic capture forces in HGMS are calculated for infinite arrays of elliptical and circular wires, and sheet matrices. The forces for elliptical wire arrays are obtained by summation of magnetic potentials due to magnetic surface charges. Matrices for selective diamagnetic capture are studied and evidence of capture presented.
Keywords :
Magnetic separation; Cameras; Geometry; Heart; Magnetic fields; Magnetic forces; Magnetic materials; Magnetic separation; Paramagnetic materials; Process control; Wire;
Journal_Title :
Magnetics, IEEE Transactions on
DOI :
10.1109/TMAG.1981.1061701