DocumentCode :
987012
Title :
Relevance of complex normalisation in precision reflectometry
Author :
Woods, Don
Author_Institution :
Private Address, Amersham, UK
Volume :
19
Issue :
15
fYear :
1983
Firstpage :
596
Lastpage :
598
Abstract :
The high accuracy now being claimed for precision reflectometers, calibrated with air-dielectric line standards, lead to a significant difference between reflection coefficients normalised to a nominal real characteristic impedance and the complex characteristic impedance of these standards. Examples are given of the spirals obtained with variable-length lines at 300 MHz.
Keywords :
electric impedance; measurement standards; reflectometry; 300 MHz; air-dielectric line standards; characteristic impedance; complex normalisation; precision reflectometry; reflection coefficients; spirals; variable-length lines;
fLanguage :
English
Journal_Title :
Electronics Letters
Publisher :
iet
ISSN :
0013-5194
Type :
jour
DOI :
10.1049/el:19830407
Filename :
4247902
Link To Document :