DocumentCode :
988064
Title :
Digital Domain Measurement and Cancellation of Residue Amplifier Nonlinearity in Pipelined ADCs
Author :
Murmann, Boris ; Boser, Bernhard E.
Author_Institution :
Stanford Univ., Stanford
Volume :
56
Issue :
6
fYear :
2007
Firstpage :
2504
Lastpage :
2514
Abstract :
Digital correction and calibration techniques have been extensively used to cancel linear circuit imperfections in pipelined analog-to-digital converters (ADCs). The self-calibration technique proposed in this paper provides a means of measuring and canceling nonlinear errors of interstage amplifiers in the digital domain. The calibration of nonlinearity coefficients is based on pseudorandom signal modulation and evaluation of digital code histograms. The scheme does not introduce additional precision hardware or test signals and operates in the background without interrupting normal converter operation. The simulation results of a 12-bit ADC show that the calibration is capable of improving the effective number of bits from 7 to 11.8 while achieving parameter adaptation time constants on the order of 100 ms at a sampling rate of 100 MS/s.
Keywords :
amplifiers; analogue-digital conversion; amplifier; analog-to-digital converters; digital code histograms; digital domain measurement; pipelined ADC; pseudorandom signal modulation; Analog-digital conversion; Calibration; Digital modulation; Distortion measurement; Error correction; Gain; Histograms; Linear circuits; Modulation coding; Nonlinear distortion; Adaptive systems; analog–digital conversion; calibration; linearization techniques; parameter estimation;
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/TIM.2007.907950
Filename :
4389123
Link To Document :
بازگشت