Title :
Compression in Wearable Sensor Nodes: Impacts of Node Topology
Author :
Imtiaz, Syed Anas ; Casson, A.J. ; Rodriguez-Villegas, Esther
Author_Institution :
Dept. of Electr. & Electron. Eng., Imperial Coll. London, London, UK
Abstract :
Wearable sensor nodes monitoring the human body must operate autonomously for very long periods of time. Online and low-power data compression embedded within the sensor node is therefore essential to minimize data storage/transmission overheads. This paper presents a low-power MSP430 compressive sensing implementation for providing such compression, focusing particularly on the impact of the sensor node architecture on the compression performance. Compression power performance is compared for four different sensor nodes incorporating different strategies for wireless transmission/on-sensor-node local storage of data. The results demonstrate that the compressive sensing used must be designed differently depending on the underlying node topology, and that the compression strategy should not be guided only by signal processing considerations. We also provide a practical overview of state-of-the-art sensor node topologies. Wireless transmission of data is often preferred as it offers increased flexibility during use, but in general at the cost of increased power consumption. We demonstrate that wireless sensor nodes can highly benefit from the use of compressive sensing and now can achieve power consumptions comparable to, or better than, the use of local memory.
Keywords :
body area networks; data compression; electroencephalography; medical signal processing; patient monitoring; wireless sensor networks; EEG signals; compression power performance; data storage; data transmission; electroencephalography; human body monitoring; low-power MSP430 compressive sensing; node topology; on-sensor-node local storage; online low-power data compression; power consumption; signal processing; wearable sensor nodes; wireless sensor nodes; wireless transmission; Compressed sensing; Electroencephalography; Power demand; Topology; Transmitters; Wireless communication; Wireless sensor networks; Body area networks; MSP430; compressive sensing; electroencephalogram (EEG); low-power consumption; wearable medical sensors;
Journal_Title :
Biomedical Engineering, IEEE Transactions on
DOI :
10.1109/TBME.2013.2293916