DocumentCode :
990598
Title :
Line fault prediction and location in echo cancelling data transmission systems
Author :
Shorrock, G.
Author_Institution :
British Telecom Research Laboratories, Ipswich, UK
Volume :
20
Issue :
1
fYear :
1984
Firstpage :
24
Lastpage :
25
Abstract :
Theoretical and practical results are presented which show that the tap coefficients of an echo cancelling modem can be used as an aid to line fault prediction and location. It is indicated that in some cases it is possible to identify a line fault before the transmission performance is seriously impaired.
Keywords :
data communication systems; echo suppression; modems; echo cancelling data transmission systems; line fault location; line fault prediction; modem; tap coefficients; transmission performance;
fLanguage :
English
Journal_Title :
Electronics Letters
Publisher :
iet
ISSN :
0013-5194
Type :
jour
DOI :
10.1049/el:19840018