DocumentCode :
991531
Title :
A new high-sensitive magneto-optic readout technique and its application to Co-Cr film
Author :
Gomi, Manabu ; Abe, Masanori
Author_Institution :
Tokyo Institute of Technology, Meguro-ku, Tokyo, Japan.
Volume :
18
Issue :
6
fYear :
1982
fDate :
11/1/1982 12:00:00 AM
Firstpage :
1238
Lastpage :
1240
Abstract :
A new high-sensitive magneto-optic readout technique, which allows detection of a relatively small magneto-optic rotation angle, is proposed. This technique essentially consists of a polarization modulation method ( which allows high-sensitive readout ) and a differential method ( which allows high-speed readout ). Applying this technique to a Co-Cr film ( Cr∼ 21.5 at. % ) with perpendicular anisotropy, Kerr rotation as small as 4.3´ was detected at a signal-to-noise ratio (SNR) of about 34 dB in a 1 MHz bandwidth using a 25 mW He-Ne laser (λ = 632.8 nm ). The SNR was improved 17 dB compared to that obtained by conventional DC method. This technique is promising in the high-sensitive read-out with Co-Cr film.
Keywords :
Magnetooptic memories; Anisotropic magnetoresistance; Magnetic films; Magnetic heads; Magnetooptic effects; Magnetooptic recording; Mirrors; Optical modulation; Optical polarization; Perpendicular magnetic recording; Signal to noise ratio;
fLanguage :
English
Journal_Title :
Magnetics, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9464
Type :
jour
DOI :
10.1109/TMAG.1982.1062141
Filename :
1062141
Link To Document :
بازگشت