• DocumentCode
    991709
  • Title

    Inversion of radiometric data from biological tissue by an optimisation method

  • Author

    Schaller, G.

  • Author_Institution
    Universitÿt Erlangen-Nÿrnberg, Institut fÿr Hochfrequenztechnik, Erlangen, West Germany
  • Volume
    20
  • Issue
    9
  • fYear
    1984
  • Firstpage
    380
  • Lastpage
    382
  • Abstract
    The temperature profile in the depth of a biological tissue is reconstructed from multispectral microwave radiometric data using an optimisation strategy. Starting from a simplified model with an assumed temperature distribution, radiometric data for different frequencies (skin depths) are computed. After adding `measurement noise¿, this computer-simulated data set is then inverted by the pattern-search strategy to yield a reconstructed temperature profile.
  • Keywords
    biological techniques and instruments; biothermics; optimisation; radiometry; biological tissue; multispectral microwave radiometry; optimisation method; pattern-search strategy; radiometric data; skin depths; temperature profile;
  • fLanguage
    English
  • Journal_Title
    Electronics Letters
  • Publisher
    iet
  • ISSN
    0013-5194
  • Type

    jour

  • DOI
    10.1049/el:19840263
  • Filename
    4248707