DocumentCode
992651
Title
Harmonic Method of Calibrating a Wave Meter
Author
Chaffee, E. Leon
Author_Institution
Department of Physics, Harvard University, Cambridge, Massachusetts
Volume
5
Issue
5
fYear
1917
Firstpage
357
Lastpage
360
Abstract
The output of an electron relay oscillator is passed thru a non-resonant, rectifying circuit. The rectified radio frequency is rich in upper harmonics. These are used to calibrate a wave meter after a limited range thereof has been calibrated by another and absolute method. Details of the requisite procedure are given.
Keywords
Alternators; Calibration; Circuits; Coils; Electrons; Physics; Radio frequency; Rectifiers; Relays; Solenoids;
fLanguage
English
Journal_Title
Radio Engineers, Proceedings of the Institute of
Publisher
ieee
ISSN
0731-5996
Type
jour
DOI
10.1109/JRPROC.1917.217332