• DocumentCode
    993595
  • Title

    Electrically Welded Structures Under Dynamic Stress

  • Author

    Stone, Morris ; Ritter, J.G.

  • Author_Institution
    Mechanical Engineer, Westinghouse Elec. & Mfg. Co., East Pittsburgh, Pa.
  • Volume
    49
  • Issue
    3
  • fYear
    1930
  • fDate
    7/1/1930 12:00:00 AM
  • Firstpage
    832
  • Lastpage
    837
  • Abstract
    In the general application of welding to various types of constructions, those structures carrying variable stress have been least adapted to fabricated construction. In the present paper it is shown that by properly considering such factors as maximum working stress, residual welding stresses, and stress concentration, it is indeed possible to weld any type of structure without fear of trouble. Many various cases of such structures are described as to their method of fabrication and success of operation.
  • Keywords
    Circuit testing; Impedance; Integrated circuit interconnections; Load flow; Power generation economics; Power system interconnection; Regulators; Voltage control; Welding;
  • fLanguage
    English
  • Journal_Title
    American Institute of Electrical Engineers, Transactions of the
  • Publisher
    ieee
  • ISSN
    0096-3860
  • Type

    jour

  • DOI
    10.1109/T-AIEE.1930.5055586
  • Filename
    5055586