• DocumentCode
    994004
  • Title

    Capacitive charge division readout of a double-sided germanium strip detector

  • Author

    Inderhees, S.E. ; Kroeger, R.A. ; Johnson, W.N. ; Kinzer, R.L. ; Kurfess, J.D. ; Gehrels, N.

  • Author_Institution
    Universities Space Res. Assoc., Washington, DC, USA
  • Volume
    42
  • Issue
    4
  • fYear
    1995
  • fDate
    8/1/1995 12:00:00 AM
  • Firstpage
    428
  • Lastpage
    431
  • Abstract
    We have implemented a capacitive charge-division readout for a germanium 5×5 orthogonal strip detector. We present measurements of non-linearity, and of energy and position resolution as a function of energy (60 and 662 keV) and of network capacitance. Energy and position non-linearities, which are worse for low capacitance networks, appear in the response along the charge division network, as well as along the length of each detector strip. The nonlinearities can be corrected by using an independent gain calibration for each pixel, allowing for use of a lower capacitance charge division network which provides better position resolution
  • Keywords
    calibration; detector circuits; elemental semiconductors; germanium radiation detectors; nuclear electronics; position sensitive particle detectors; 60 keV; 662 keV; Ge; capacitive charge division readout; double-sided strip detector; energy resolution; independent gain calibration; low capacitance networks; network capacitance; nonlinearity; orthogonal strip detector; pixel detector; position resolution; Capacitance measurement; Capacitors; Detectors; Energy measurement; Energy resolution; Face detection; Germanium; Linearity; Parasitic capacitance; Strips;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.467807
  • Filename
    467807