Abstract
The experimental study leading to the determination of the sensitivity needed for protecting the Fermilab Doubler from damage during quenches is presented. The quench voltage thresholds involved were obtained from measurements made on Doubler cable of resistance × temperature and voltage × time during quenches under several currents and from data collected during operation of the Doubler Quench Protection System as implemented in the B-12 string of 20 magnets. At 4kA, a quench voltage threshold in excess of 5.0V will limit the peak Doubler cable temperature to 452K for quenches originating in the magnet coils whereas a threshold of 0.5V is required for quenches originating outside of coils.
Keywords
Accelerator magnets, superconducting; Magnetic confinement, safety; Circuits; Conductors; Electrical resistance measurement; Plasma temperature; Protection; Superconducting cables; Superconducting coils; Superconducting magnets; Threshold voltage; Time measurement;