Title :
High efficiency CsI(Tl)/HgI2 gamma ray spectrometers
Author :
Wang, Y.J. ; Patt, B.E. ; Iwanczyk, J.S. ; Cherry, S.R. ; Shao, Y.
Author_Institution :
Xsirius Inc., Camarillo, CA, USA
fDate :
8/1/1995 12:00:00 AM
Abstract :
CsI(Tl)/HgI2 gamma-ray spectrometers have been constructed using 0.5" diameter detectors which show excellent energy resolution: 4.58% FWHM for 662 keV 137Cs gamma-ray photons. Further efforts have been focused on optimization of larger size (⩾1" diameter) detector structures and improvement of low noise electronics. In order to take full advantage of scintillation detectors for high energy gamma-rays, larger scintillators are always preferred for their higher detection efficiencies. However the larger capacitance and higher dark current caused by the larger size of the detector could result in a higher FWHM resolution. Also, the increased probability of including nonuniformities in larger pieces of crystals makes it more difficult to obtain the high resolutions one obtains from small detectors. Thus for very large volume scintillators, it may necessary to employ a photodiode (PD) with a sensitive area smaller than the cross-section of the scintillator. Monte Carlo simulations of the light collection. For various tapered scintillator/PD configuration were performed in order to find those geometries which resulted in the best light collection. According to the simulation results, scintillators with the most favorable geometry, the conical frustum, have been fabricated and evaluated. The response of a large conical frustum (top 2" bottom-1" 2" high) CsI(Tl) scintillator coupled with a 1" HgI2 PD was measured. The energy resolution of the 662 keV peak was 5.57%. The spectrum shows much higher detection efficiency than those from smaller scintillators, i.e., much higher peak-to-Compton ratio in the spectrum
Keywords :
Monte Carlo methods; caesium compounds; gamma-ray detection; gamma-ray spectrometers; mercury compounds; photodiodes; semiconductor counters; solid scintillation detectors; thallium; 662 keV; CsI:Tl; HgI2; Monte Carlo simulations; conical frustum; dark current; detection efficiencies; energy resolution; high efficiency gamma ray spectrometers; large volume scintillators; light collection; low noise electronics; optimization; peak-to-Compton ratio; photodiode; scintillation detectors; semiconductor detector; Capacitance; Crystals; Dark current; Energy resolution; Gamma ray detection; Gamma ray detectors; Geometry; Scintillation counters; Solid scintillation detectors; Spectroscopy;
Journal_Title :
Nuclear Science, IEEE Transactions on