• DocumentCode
    995735
  • Title

    Telegraph Transmission Testing Machine

  • Author

    Bramhall, F.B.

  • Author_Institution
    Engg. Department, Western Union Telegraph Co., 60 Hudson Street, New York, N. Y.
  • Volume
    50
  • Issue
    2
  • fYear
    1931
  • fDate
    6/1/1931 12:00:00 AM
  • Firstpage
    404
  • Lastpage
    412
  • Abstract
    In the study of telegraph transmission efficiencies and the analysis of signal distortions a suitable signal recording device is a first requisite. This paper describes a machine developed for the purpose. This machine furnishes a graphical and permanent record of the received signals and shows their relation to sent signals, in a form which is most convenient for comparison and analysis. The unusual arrangement of the recorder is such as to adapt it especially to the study of both characteristic and fortuitous distortions and, in general, to the comparison and absolute measurement of short time intervals. Time intervals of one ten-thousandth of a second in the opening and closing of electrical circuits are graphically recorded without resort to photographic means.
  • Keywords
    Circuit testing; Distortion measurement; Instruments; Pulse circuits; Pulse measurements; Relays; Signal analysis; Telegraphy; Time measurement;
  • fLanguage
    English
  • Journal_Title
    American Institute of Electrical Engineers, Transactions of the
  • Publisher
    ieee
  • ISSN
    0096-3860
  • Type

    jour

  • DOI
    10.1109/T-AIEE.1931.5055808
  • Filename
    5055808