• DocumentCode
    998454
  • Title

    Breakdown of Glass with Alternating Potentials

  • Author

    Kenney, N.D. ; Luery, A.M. ; Moriaty, J.D.

  • Author_Institution
    Massachusetts Institute of Technology.
  • Volume
    51
  • Issue
    2
  • fYear
    1932
  • fDate
    6/1/1932 12:00:00 AM
  • Firstpage
    404
  • Lastpage
    408
  • Abstract
    Previous tests on the breakdown of glass with direct potentials indicated the existence of three different regions of breakdown. The present paper describes similar tests on alternating potentials. The following conclusions are reached: 1. Three distinct regions of breakdown are obtained on alternating current as well as on direct current. 2. In the disruptive and intermediate regions, breakdown occurs at an alternating peak voltage approximately equal to the direct breakdown voltage. 3. In the thermal region, breakdown occurs at an alternating peak voltage somewhat lower than the direct breakdown voltage.
  • Keywords
    Breakdown voltage; Electric breakdown; Glass; Solids; Temperature measurement; Voltage transformers;
  • fLanguage
    English
  • Journal_Title
    American Institute of Electrical Engineers, Transactions of the
  • Publisher
    ieee
  • ISSN
    0096-3860
  • Type

    jour

  • DOI
    10.1109/T-AIEE.1932.5056084
  • Filename
    5056084