DocumentCode
998826
Title
Temperature measurements of a high-power microwave feedhorn window
Author
Hoppe, Daniel J. ; Perez, Raul M. ; Glazer, Stuart D.
Author_Institution
Jet Propulsion Lab., Pasadena, CA, USA
Volume
39
Issue
3
fYear
1990
fDate
6/1/1990 12:00:00 AM
Firstpage
501
Lastpage
503
Abstract
Temperature measurements of a high-power microwave feedhorn window during transmitter operation at 365 kW CW and 8.5 GHz made using an imaging infrared radiometer are discussed. The window under investigation was constructed of HTP-6, a high-thermal-performance material developed to shield the Shuttle Orbiter from the heat of reentry. The measurement technique is described and experimental results are presented. The window performed adequately at 365 kW CW with a center temperature of 475°C. The tests verify that HTP-6 can be used as a window material or a support structure in high-power waveguide at power densities of 1.47 kW/cm2 for extended periods of time, with no change in its mechanical characteristics
Keywords
infrared detectors; microwave measurement; radar transmitters; radiometers; temperature measurement; 365 kW; 475 degC; 8.5 GHz; HTP-6; high-power microwave feedhorn window; high-power waveguide; imaging infrared radiometer; mirror; temperature measurement; transmitter operation; Electromagnetic heating; Infrared imaging; Materials testing; Measurement techniques; Microwave imaging; Microwave radiometry; Optical imaging; Radio transmitters; Temperature measurement; Waveguide transitions;
fLanguage
English
Journal_Title
Instrumentation and Measurement, IEEE Transactions on
Publisher
ieee
ISSN
0018-9456
Type
jour
DOI
10.1109/19.106280
Filename
106280
Link To Document